MultiProx System Overview
The MultiProx system is designed to retrofit existing Schlage/Westinghouse Security Electronics (SE) systems
that use 2814/2815 type sensors, 708/808 type Controllers and SE774 Multiple Switch Monitors MSM(s). The
MultiProx system reads Schlage/Westinghouse (SE) Command Keys (1030, 1040, or 1050) along with HID
ProxCard II Cards. It interfaces to all host systems that have standard Wiegand electrical interfaces. The MultiProx
system uses the existing coax cable and provides monitoring input points and associated outputs that are the
functional equivalent of the SE MSM (Multiple Switch Monitor) module. The MultiProx system directly replaces the
existing SE components without major modifications to the existing mounting hardware. This includes the
mounting holes and cable locations. The MultiProx Controller replaces the SE 708(S) or 808(S), the MultiProx
Reader replaces the SE Sensors, and the MultiProx HSM (HID Switch Monitor) replaces the SE MSM.
MultiProx System Layout Diagram - Figure 1
Wiegand and
Maximum - 8 Reader Channels
** - Alpha 1295 or Equivalent per channel
SYSTEM
Wiegand Interface
Relay outputs
Reader 1 data **
Reader 8 data **
Channel
8
Channel 1
Reader
Reader
Note - HSMs are only required when input (REX/Door Sense/ Aux. inputs) wiring is local to the reader door.
*** - Alpha 1292 or Equiv. per output
P/N 6020ANC00
P/N 6020ANC00
Figure 1
Description/Operation
The MultiProx Controller is the center of the MultiProx system. The Controller scans the Readers for HID or
Schlage/Westinghouse (SE) access control cards, communicates with the HSMs for switch status changes and
communicates with the Reader for LED and Beeper control. When a card is read, the Controller outputs the card
data over the Wiegand interface. When a monitored contact has a status change, the Controller switches the relay
output that provides status of the HSM monitored switch that changed. See Figure 1. The Controller has a default
mode for controlling the Reader beeper and LEDs, as well as an external (Host) controlled beeper and LED option.
Parts List
1) MultiProx Controller p/n 6000ANN00 qty 1 (included)
2) This Installation Sheet p/n 6000-900 qty 1 (included)
3) RS3222 Screwdriver p/n 68-0002-01 qty 1 (included)
3) Cable, coax - RG/6 or SE 9284 As required/installed (1000 feet maximum per Reader channel)
65% shield, copper center, 18AWG
4) Cable, multi-conductor Wiegand As required (500 ft maximum per Reader channel)
5) Power Supply Requirements Linear type recommended, 20.0 - 28.5 VDC @ 2.0 Amps