Schlage/Westinghouse Card Types - Figure 2
xxxxx Yyyy zzzz
1030
xxxxx = 5 digit octal card number
Yyyy = 4 digit facility code
Y = facility code letter
yyy = facility code number (decimal)
xxxxxxxx yyyyyyy L
xxxxxxxx = 8 digit decimal card number
yyyyyyy = 7 digit data code
L = 1 digit library code (optional)
1050
xxxxxx Yyyy zzz
xxxxxx = 6 digit octal card number
Yyyy = 4 digit facility code
Y = facility code letter
yyy = facility code number (decimal)
1040
Wiegand Data Formats - 32 bit output description
The data format consists of 32 bits of data when switch 2 position 4 is off. Two parity bits cover half of the
message respectively much like the standard 26 bit format. The 1030 and 1040 cards have facility codes and card
numbers, whereas, the 1050 cards only have a card number.
Wiegand Data Formats - 26 bit output description
The data format consists of 26 bits of data when switch 2 position 4 is on. The two parity bits cover half of the
message. The 1030 and 1040 cards have facility codes and card numbers, whereas, the 1050 cards only have a
card number. When sw2.4 is on, the 32 bit card code is transformed into 26 bits. For 1030 and 1040 cards, the
11 bit facility code is reduced to 8 bits where the 3 most significant bits are dropped. The 1030 15 bit card code is
preserved but becomes a 16 bit card code with 0 as the most significant bit. The 1040 card code is reduced from
18 bits to 16 bits, where the 2 most significant bits are dropped. For 1050 cards, there is no facility code, so the 25
bit card code is reduced to 24 bits with the most significant bit being dropped.