HSM model no. 6020ANC00
Operating Limits
Operating voltage range 14 - 28.5VDC Supplied by the controller
Absolute maximum voltage 28.5VDC
Current consumption 20mA
Reverse voltage protection On coax F -type input connectors
Environmental
Enclosure rating Indoor only
Enclosure None - PCB only
Weight 3 oz.
Operating temperature range -40 to 65°C (-40 to 150°F)
Storage temperature -40 to 85°C (-40 to 185°F)
Operating humidity range 5 to 95% Non-condensing
Operating vibration limit .04 G
2
/Hz 20 - 2000Hz
Operating shock limit 30g, 11mS half sine
Operating parameters
Connector F type PCB mount
HSM Communication speed 15 -150mS
Inputs Up to 4 - Monitors normally open or normally closed contacts
Termination resistor - 36Kohm Normally open - Resistor in parallel, normally closed - series
Note: The above are recommended installation procedures. All local, state and national electrical codes