____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com - MultiProx Controller Installation Manual 6000-900 Rev F 26 of 27
3/32” screw head, 3.5mm spacing
Maximum conductor size18 AWG
Pin-out - TBR1 thru TBR8 1 - RLY-A Contact selected by J1-A thru J8-A
2 - COM-A Common for relay 1A thru 8A
3 - RLY-B Contact selected by J1-B thru J8-B
4 - COM-B Common for relay 1B thru 8B
5 - RLY-C Contact selected by J1-C thru J8-C
6 - COM-C Common for relay 1C thru 8C
7 - RLY-D Contact selected by J1-D thru J8-D
8 - COM-D Common for relay 1D thru 8D
Default Board jumper settings
JMP1 IN (Ramp)
JMP2 IN (Count)
JMP3 IN (Prox input)
JMP4 OUT (Hit disable)
JMP5 IN (Hit filter input)
J9 1 to 3 (Processor setting)
J10 1 to 2 (Processor setting)
MultiProx Reader - model no. 5385AGB00 (back) or 5385AGS00 (side)
Operating Limits
Operating voltage range 14 - 28.5VDC Supplied by the Controller
Absolute maximum voltage 28.5VDC
Current consumption Prox mode - 85mA, Sweep mode - 25mA Average - 45mA
Reverse voltage protection On coax F type input connector
Environmental
Enclosure rating Outdoor rated to NEMA 4X
Enclosure material Polycarbonate
Enclosure finish .002” Matte - pebble
Enclosure color Gray
Weight 15 oz.
Operating temperature range -40 to 65°C (-40 to 150°F)
Storage temperature -40 to 85°C (-40 to 185°F)
Operating humidity range 5 to 95% Non-condensing
Operating vibration limit .04 G
2
/Hz 20 - 2000Hz
Operating shock limit 30g, 11mS half sine
Operating parameters
Read distance/ProxCard II 2.5 - 4 inches over operating limits, 3.0 inches typical
Read distance/Schlage/WSE 1050 .75 - 3 inches over operating limits, 1.75 inches typical
Read distance/Schlage/WSE 1030/1040 1.0 - 3.5 inches over operating limits, 2.0 inches typical
Excitation frequency - Prox mode 125kHz generated internally
Excitation frequency - Sweep mode 2-30MHz generated on the controller
Minimum clearance from metal 4 inches behind, 2 inches on the side
Minimum clearance from wiring 6 inches
Minimum metal enclosure size 14” square by 5” deep no cover
Connector F type rear mount